Belden’s New Adaptive Enclosure Heat Containment System "Greens" The Data Center By Slashing Cooling Costs
Released on: March 10, 2009, 7:35 am
Author: Belden
Industry: Computers
RICHMOND, IN – Belden (NYSE: BDC), a world leader in the development of signal
transmission products for industrial, enterprise, building management, broadcast,
and security applications, has introduced a new adaptive enclosure heat containment
(AEHC) system for data centers that will ensure the entire room is normalized with
cold air to just the right amount, with no wasteful oversupply of cooling.
Carl Bruckner, General Manager of Belden’s Cable Management Group, states: “The AEHC
system is a key addition to Belden’s enclosure products, allowing our partners to
effectively manage the deployment of high density, high heat load equipment in both
new and existing data centers.”
In the new Belden system, a pressure reading made by a sensor inside the enclosure
plenum modulates the rotational speed of the fans in the two cartridges mounted atop
the enclosure. The speed is varied so that they pull out exactly the correct amount
of air from the enclosure and send it back to the air conditioner return via a
ceiling plenum.
The process of cooling enclosures in a data center today wastes excessive amounts of
energy, largely due to oversupply of cold air by computer room air conditioner
(CRAC) units attempting to compensate inefficiency in the enclosure cooling process.
A recent study on 19 large computer rooms found that, on average, the amount of cold
air supplied to a data center room is 2.6 times the amount of cold air actually
consumed by the IT load. The CRAC is oversupplying the room with cold air to
overcome both bypass leakage and the effects of hot/cold mixing. The result is a
significant waste of energy and dollars.
However, because of its innovative heat containment design, the new Belden AEHC
system overcomes these problems. Since it completely separates the hot and cold side
of operations, the room will be normalized with cool air which never experiences
mixing with exhaust heat from the enclosure. The bypass problem is eliminated, too.
There is no need to oversupply cold air to the room.
The physical position of the CRAC unit and its proximity to the enclosures are no
longer a concern, a fact which greatly simplifies the challenge of data room
infrastructure design. Cool air can be fed to the computer room via a raised floor
or an overhead duct which enhances your freedom of infrastructure design.
When designing a totally new data center with the AEHC system, you can now install
bigger and fewer CRAC units, instead of relying on many smaller units that are less
efficient. And when retrofitting an existing room, you can use the same amount --
and same type -- of cooling equipment currently installed. In either scenario,
Belden's advanced management software will help you better control your IT
environment by giving you real time assessment of enclosure cooling load or demand.
You will be able to deploy more IT load in the same room, a great efficiency benefit
in today's economy. If you have space left in your enclosures but aren't deploying
more devices there because your cooling system is already at full capacity, you can
retrofit Belden's new heat containment system on those enclosures that have the
highest heat loads, to be able to host even more IT equipment.
As a bonus, the AEHC system increases the temperature differential between the inlet
and outlet temperatures of the CRAC unit for much greater operational efficiency,
giving you an important savings in energy consumption. With no mixing of hot and
cold air, it is possible to raise the temperature of the cooling air supplied to
enclosures to be closer to the ASHRAE recommended upper limit. The cold/hot air
paths are fully separated by the system, so the CRAC supplies less air to the room
at a higher temperature, and still assures better cooling with no hot spots.
For more information about the AEHC system, download NP 300 at
http://www.belden.com, or contact Belden, P.O. Box 1980, Richmond, Indiana 47375,
1.800.BELDEN.1. FAX: 765.983.5294.
About Belden
Belden is a customer focused company. We ensure that our customers’ communications
infrastructure issues are resolved and that they benefit from the best signal
transmission performance for their investment. We deliver leading-edge copper and
fiber cabling/connectivity systems, wireless technologies, and active switch
devices. We employ customer-centric go-to-market strategies and we implement and
retain world class manufacturing processes. Our partners span the globe, helping our
customers design, install, operate and maintain their communications applications.
And our experience is vast, including expertise in Enterprise, Industrial,
Infrastructure, Transportation, Professional and Enterprise Audio and Video, and
Government applications. To obtain additional information contact Investor Relations
at 314-854-8054, or visit our website at http://www.belden.com.
Belden
Alison McCreath
1.800.BELDEN.1
Agency Contact:
Adventive Marketing, Inc.
Janet Killen
847.590.1110